Call Us

  • Telephone:  (03) 9551 3077
  • Facsimile:     (03) 9551 2120
  • International Code: (+61 3)

Connection & Installation Instructions

All steel fixings can be replaced with welded connections.
Check with your/our Engineer to determine the appropriate design loads for your floor.

Hopleys Steel Diagram01

Hopleys Steel Diagram01

HopleysSteelDiagram01 Hopleys Steel Diagram01

Hopleys Steel Diagram02

Hopleys Steel Diagram02

Hopleys Steel Diagram02 Hopleys Stee lDiagram02

Hopleys Steel Diagram03

Hopleys Steel Diagram03

Hopleys Steel Diagram03 Hopleys Steel Diagram03

Hopleys Steel Diagram04

Hopleys Steel Diagram04

Hopleys Steel Diagram04 Hopleys Steel Diagram04

Hopleys Steel Diagram05

Hopleys Steel Diagram05

Hopleys Steel Diagram05 Hopleys Steel Diagram05

Hopleys Steel Diagram06

Hopleys Steel Diagram06

Hopleys Steel Diagram06 Hopleys Steel Diagram06

Hopleys Steel Diagram07

Hopleys Steel Diagram07

Hopleys Steel Diagram07 Hopleys Steel Diagram07

Hopleys Steel Diagram08

Hopleys Steel Diagram08

Hopleys Steel Diagram08 Hopleys Steel Diagram08

Hopleys Steel Diagram09

Hopleys Steel Diagram09

Hopleys Steel Diagram09 Hopleys Steel Diagram09

Hopleys Steel Diagram10

Hopleys Steel Diagram10

Hopleys Steel Diagram10 Hopleys Steel Diagram10

Hopleys Steel Diagram11

Hopleys Steel Diagram11

Hopleys Steel Diagram11 Hopleys Steel Diagram11

Hopleys Steel Diagram12

Hopleys Steel Diagram12

Hopleys Steel Diagram12 Hopleys Steel Diagram12

Hopleys Steel Diagram13

Hopleys Steel Diagram13

Hopleys Steel Diagram13 Hopleys Steel Diagram13

Hopleys Steel Diagram14

Hopleys Steel Diagram14

Hopleys Steel Diagram14 Hopleys Steel Diagram14

Hopleys Steel Diagram15

Hopleys Steel Diagram15

Hopleys Steel Diagram15 Hopleys Steel Diagram15

Hopleys Steel Diagram16

Hopleys Steel Diagram16

Hopleys Steel Diagram16 Hopleys Steel Diagram16

Hopleys Steel Diagram17

Hopleys Steel Diagram17

Hopleys Steel Diagram17 Hopleys Steel Diagram17

Hopleys Steel Diagram18

Hopleys Steel Diagram18

Hopleys Steel Diagram18 Hopleys Steel Diagram18

Installation Instructions

  • Extra joists should be added under non load bearing, internal partition walls which are within 80% of their maximum span.
  • Add extra joists at half spacing under spa baths or water beds.
  • For all load bearing internal walls or point loads, please consult with your Hopleys representative.
  • Do not notch top or bottom chords or remove webs. If a web needs to be removed, please consult with your Hopleys representative.
  • We highly recommend screwing the sheets to the joists using a QuikDrive™ PRO250 Auto-Feed Screw Driving System, which can be purchased or hired from your Hopleys representative. You will require approximately 29 screws per 3600mm x 900mm sheet.
  • Alternatively the floor sheets can be nailed down using hardened twist nails available from various manufacturers such as Senco, Duo-Fast, Bostitch and Paslode.
  • Ensure that once the floor has been fixed that any nails protruding through and touching the webs are bent away a few millimetres using pliers.

Floor Sheeting - we recommend the following minimum sheet flooring thickness:
1.5kPa Floor Load, Joists @ 450mm c/c
19mm Structaflor™ 'Yellow Tongue' Particleboard Flooring
17mm Plywood, F11
1.5kPa Floor Load, Joists @ 600mm c/c
22mm Structaflor™ 'Red Tongue' Particleboard Flooring
17mm Plywood, F14
3.0kPa Floor Load, Joists @ 450mm c/c
22mm Structaflor™ 'Red Tongue' Particleboard Flooring
17mm Plywood, F14
3.0kPa Floor Load, Joists @ 600mm c/c
25mm Structaflor™'Blue Tongue' Heavy Duty Particleboard Flooring
19mm Plywood, F14
5.0kPa Floor Load, Joists @ 450mm c/c
25mm Structaflor™ 'Blue Tongue' Heavy Duty Particleboard Flooring
19mm Plywood, F14
5.0kPa Floor Load, Joists @ 600mm c/c
25mm Structaflor™ 'Blue Tongue' Heavy Duty Particleboard Flooring
21mm Plywood, F14

An approved construction grade adhesive should be used to bond the sheet flooring to the joists. Approximately 2 tubes of 850ml will be required per 10 - 3600mm x 900mm sheets.

Spacing and Span

"Spacing" is the centre to centre distance between structural members and is assumed to be 450mm unless noted otherwise.

"Span" is the face to face distance between points of support for the structural members.

"Single Span" is the span of a member supported at both ends with no intermediate support. This is also known as "simply supported".

"Continuous Span" is when a member has support at both ends and also at one or more evenly spaced points between the ends.